#Dog# #12Months# #5.6kg# #radius-distal-open fracture# #radius-distal-comminuted fracture# #ulna-distal-open fracture# #ulna-distal-comminuted fracture#

20210420 -【Comminuted and open fracture of distal radius and ulna】A Poodle, fixed with HyProtect-PRCL-S antimicrobial plasma coating plate system successfully

Kunming Yijia Animal HospitalDr. Li2021-05-06 514

A Poodle, one year old, male, 5.6kg, fell down from the second floor, caused a comminuted and open fracture of left distalradius and ulna, fixed with the BlueSAO HyProtect-PRCL-S6.5mm antimicrobial plasma coating locking plate of T-shape. The reduction was good. The surgery was completed successfully. Hope the guy recovery soon!

The MicroSilver antimicrobial plasma coatings come from German Bio-Gate company. This antimicrobial plasma coating can release Ag+( silver ion) in body more than 100 days for resisting infection to kill 99.9 percent of bacteria.

Thanks for Dr. Lifrom Kunming Yijia Animal Hospital of Yunnan province bringing us the case.



Orthopedic Instruments We Use BlueSAO