#Dog# #72Months# #3kg# #tibia-other position-other fracture#

20220914-【Fracture of tibia】A Poodle, fixed with HyProtect-PRCL-S antimicrobial plasma coating plate system successfully

Harbin Song Yisheng Animal HospitalDr. Han2022-11-07 354

A Poodle, 6 years old, male, 3kg, suffered from a fracture of tibia. He had an external fixation surgery at another hospital and the bone did not heal after the surgery. Therefore, his owner brought him to our hospital for a second surgical repair. We did the revision surgery by using the BlueSAO HyProtect-PRCL®6.5mm-antimicrobial plasma coating locking plate and the BlueSAO PRCL®-Mini 4mm pure titanium locking plate. The surgery was successful. Hecan run15 days after the surgery.

Hyprotect silver ion antibacterial coating is a black technology (a technology that is far more advanced than those of the real world) from Bio-Gate, Germany, specifically for fracture types with a high risk of infection (infectious fracture repair, open fracture, etc.). It can continuously precipitate silver ions in the body for more than 100 days, and can be effective for long-term antibacterial, with an antibacterial rate of 99.9%.

Thanks to Dr. Han from Harbin Song Yisheng Animal Hospital of Heilongjiang province bringing us the case.



Orthopedic Instruments We Use BlueSAO