#Dog# #24Months# #36.8kg# #tibia-middle-comminuted fracture# #fibula-middle-comminuted fracture#

20200319-【Comminuted fracture of middle tibia and fibula 】A Labrador,fixed with HyProtect-PRCL-L11mm antimicrobial plasma coating locking plate system successfully

Yize Animal HospitalDr. Jia2020-03-23 1049

A Labrador retriever, two years old, female, 36.8Kg, hit by a car, caused a comminuted fracture of left middle tibia and fibula, we fixed it by using one BlueSAO HyProtect-PRCL-L11mm antimicrobial plasma coating locking plates and oneφ3mmintramedullary pin. Hope her recover soon.

The MicroSilver antimicrobial plasma coatings come from GermanyBio-Gate company. This antimicrobial plasma coating can release Ag+( silver ion) in body more than 100 days for resisting infection.

Thanks for Dr. Jia from Yize Animal Hospital of Inner Mongolia bringing us the case.



Orthopedic Instruments We Use BlueSAO